Testing of Concrete Blocks
20 full size units shall be measured for length, width and height. Cored units shall also be measured for minimum thickness of face, shells and webs. From these 3 blocks are to be tested for block density, 8 blocks for compressive strength, 3 blocks for water absorption and 3 blocks for drying shrinkage and moisture movement.